Contact Us   
led panel Service Center

How to set up bus led destination display sign new manual

      2019/5/3      view:

Part1  bus led display sign control card setting.
The default factory parameters  for bus led display sign control card are as follows:(this is wifi way for control, if you order no wifi control card you can start from item 4)
pattern:AP pattern
IP address:192.168.1.222
           gateway :192.168.1.1
           subnet mask:255.255.255.0
           port:5200
           SSID:lumenchina-xx (xx  Represents the MAC address after two bits )
           Password: None 
(1) first of all, the computer is connected wirelessly to the WIFI control card. Our control card defaults to the AP mode, so we can find a corresponding WIFI.
Figure: WIFI. to connect to SSID for lumenchina-05
 


(2)manually set the IP of the computer, or it can be automatically acquired. (when the control card is STA mode, it must be manually obtained)


The IP of the computer should not be the same as the IP of the control card in the same network segment. The subnet mask and gateway should be consistent with the control card.

   (3)(3) when setup is complete,
You find  Tools  find device  search network  find control card .
(4)open setting  advance  define LED screen
 

 
In this interface you can edit or make new led setting.
Press”edit”,then input password:16888
 
For bus led display usually use C-POWER1-B control card.
ID means the control card. If you have many different led sign you can change different ID. usually no need to change.
Width means your bus led display sign the dots of width(means how many leds in the wide.
Height means your bus led sign the dots of height(means how many leds in the hight)
Color:there have 1 color 2 colors and RGB color.(according which color you bought)
Special:no need to change.just put None.
Communication type  ,which type you can choose by yourself.
For this manu we put the WIFI type of commnunication. 
Also you can change to RS232 AND 485 commnunication as below.
 
About the Port you can check by the software (tools-find device)when you connect RS232 OR 485.  When you connect correct, they will show which com port is for the contol card.
 
(5) after the parameters are set correctly, you can edit the program and click the button in the red area in the picture below to send the program 
 
In window interface  you can set the width and height.also the position etc.
 
In play item interface you can set the text, time,and add files.  
Also you can set the speed、stay、show、font、size、color and arrangement etc…
You can add more programs and windows and play item for 1 or more bus led display sign.
When you finished press send bottom  .
 



ParPPart2:Bus led display sign Controller and connection
Hardware connection


【Connection】
The keyboard connects to C-Power controller’s serial port, RS232 or RS485 can be chosen.


The keyboard’s baud rate is 115,200bps. Please set the controller’s baud rate to 115,200bps before connecting to the keyboard.


Programs edit and sending
The programs edit and sending is same to the common C-Power control card application, use the software LedCenterM to edit on the computer, and send the programs to the control card and store in the control card via serial port, network port or USB flash disk port.
The programs number will be used to select by the keyboard.
Bus led display sign program change and control
Keyboard is used to select the programs that store in the controller, and so other control command. The panel of the keyboard (membrane) is shown below:
 
Function mode 1 (P1) ——Programs selection, programs up and                          down.
After power on, the numerical code tubes on the keyboard display “ON”, after one second, the numerical code tubes display “P1”, and enter function mode 1.
Press 【 】 button to switch function mode, until the numerical code tubes display “P1”, and enter function mode 1.
When the time interval between two action overrun 8 seconds and no RUN button【 】pressed , the previous actions will be ignored, and the numerical code tubes will display “P1” again. 
When there are no new actions and after 8 seconds, the last action will be store into the controller’s flash, and it will not lose after power-down.
Function keys in function mode 1(P1)
Number button【0-9】: Program number input
ADD button【 】When select more than one program, press ADD button between two program number to build play bill.
RUN button【 】After select, press RUN to run the program(s) that has(have) selected before. The card will store the play list into the card’s flash, and it will not lose after power-down.
UP button【 】:Select next program.
DOWN button【 】: Select last program..
Other button : Keep
Programs selection 
Control method: use number buttons to input program number.
Press one or two or three number button (press more than three, will cut to use the last three numbers), corresponding of the program number.
The first 0 will discard, “01” is same to “1”.
1. Select and play one program: [number] + [RUN]
For example:
[9]+[RUN]: play no.9 program
[04]+[RUN]: play no.4 program
[12]+[RUN]: play no.12 program 
2. Select and play more than one program: [number X] + [ADD] + [numberY]…+[RUN]. 
For example:
[2]+[ADD]+[4]+[ADD]+[03]+[RUN]: order by no.2 -> no. 4 -> no.3 to play the programs, and save to flash chip on card.
[04]+[ADD]+[5]+[RUN]: play no.4 and no. 5 programs 
3. Exit the select play by remote controller.(The C-Power card will play the program as common mode, according to computer: [0] + [RUN]
——The numerical code tubes will display “Suc” when the action succeed, or display “RUN” when action was wrong.——


Notice:The program number will be “0” when the program which is chosen is out of the programs store on the controller. 




Programs up and down
When press UP button【 】, the play program’s number will add one, the numerical code tubes will display the program number which has been added..
 When press DOWN button 【 】, the play program’s number will reduce one, the numerical code tubes will display the program number which has been reduced.


Notice:The keyboard can recognize the program number by itself,  prevent the select program number beyond the programs store on the controller.


Function mode 2 (P2) ——Brightness adjustment
Press 【 】 button to switch function mode, until the numerical code tubes display “P2”, and enter function mode 2.
In function mode 2 (P2), every action will be executed immediately, when there are no new actions and after 8 seconds, the last action will be store into the controller’s flash, and it will not lose after power-down, and the numerical code tubes will display “P2” again.
Bus led sign Brightness add and reduce
When press UP button【 】, the brightness of the card (LED screen) will add one, the numerical code tubes will display the brightness level which has been added  
When press DOWN button 【 】, the brightness of card (LED screen) will reduce one, the numerical code tubes will display the brightness level which has been reduced.


Remark
When in the pattern of program selection or program up and down, press “UP”button 【 】, DOWN” button【 】, numerical code tubes display“1” “-1” in turn . Said there is something wrong with the communication circuit .